ПОМ’ЯКШУВАЧ ВОДИ З ФУНКЦІЄЮ PH-КОРЕКТОРА AUDITOR®
Features
Composition
Natural biogenic hydroxycarboxylic acids
Anionic surfactants with high surface activity
----------------------------
---------------------
Container:
5 L

AUDITOR® is a water softener (water pH corrector) with a function of dH water corrector, it is used in the preparation of a tank mixture with water with a high level of hardness, and to correct the pH level of the working solution.

The preparation contains natural biogenic hydroxycarboxylic acids, anionic surfactants with high surface activity.

  • утворює біологічно активні хелатні природні комплекси з катіонами солей жорсткості (кальцій, магній, залізо), переводячи їх у форму, яка легко засвоюється рослинами;
  • регулює рН бакової суміші до нейтральних значень, забезпечуючи стабільність низки ЗЗР, що гідролізуються за високих значень рН, втрачаючи ефективність використання.

Main functions:

  • isolates hardness ions and their negative impact on tank mix components;
  • eliminates possibility of the sediment formation in the sprayer tank when using water with increased hardness;
  • increases the technological efectiveness of foliar treatments and solves the problems of nozzle clogging that arise during the active phases of work;
  • ensures the stability of preparations which are especially sensitive to high pH values ​​of the solution, prevents decomposition and decrease in their effectiveness;
  • allows to fully reveal the potential of all tank mix components;
  • forms biologically active chelate natural complexes with cations of hardness salts (calcium, magnesium, iron), converting them into a form that is easily absorbed by plants;
  • adjusts the tank mix pH to neutral values, ensuring the stability of a number of pesticides that hydrolyze at high pH values, losing their effectiveness.

Typically, if the pH is 7.5 or higher, a number of pesticides undergo half-life in a short period of time (0.5-3 hours), so the pH value of the tank mix is ​​an important factor in ensuring the effectiveness of all tank mix components.

The formulation can be used in combination with fungicides, inoculants, pesticides, growth regulators, microfertilizers and biological products.

The solution is formed on the day of treatment according to the norms indicated on the label.

The application rate of the formulation is 25-350 mL per 100 L of water, depending on the hardness of the water. To soften water of medium hardness, 60 mL per 100 L of water is sufficient.

Download the AUDITOR® booklet

рн-коректор води

Results of laboratory studies of the AUDITOR® preparation application to water of different hardness and regulation of the pH of the used water

  • up to 100 L of water with different hardness was added to the AUDITOR® preparation with measurement of the resulting mixture pH level;
  • then 0.4 L of ORAKUL® multicomplex was added with repeated measurement of the medium pH.
Water hardness,
ppm (CaCO3)
Water hardness,
mg eq./L (Ca2+)
Water pH, units (initial)AUDITOR®, mL/100 L of waterMixture рН, unitsрН in case of adding ORAKUL® multicomplex,
units
200

400

500

1100

4

8

10

22

8

8

8

8

25

50

60

130

4.5

3.8

3.4

3.0

6.3

5.4

5.0

4.2

APPLICATION

THE RATE OF APPLICATION OF THE PREPARATION DEPENDING ON THE HARDNESS OF THE WATER

Water hardness,
ppm (CaCO3)
Water hardness,
mg eq./L (Ca2+)
Application rate of the formulation*, mL/100 L of water
200
400
500
1000
1500
2250
3250
4.0
8.0
10.0
20.0
30.0
45.0
65.0
25
50
60
120
175
260
380

*The application rate of the AUDITOR® preparation to reduce pH to a certain level depends on the composition of water hardness impurities (anions – sulfate, carbonate, chloride and cations – iron, calcium, magnesium, etc.), therefore, previous experimental selection is necessary.

To wash the spraying equipment, mix 250 mL of the product per 100 L of water and leave the mixer on for 40 minutes or more, depending on the water temperature. The washing time decreases with increasing of water temperature. Depending on the degree of contamination of the units, repeat the washing several times.

AUDITOR®

Water softener (dH-corrector) with pH-corrector function

Composition: natural biogenic hydroxycarboxylic acids, anionic surfactants with high surface activity.

Purpose: it is used in the preparation of tank mixtures with water with an increased level of hardness and for correction of the pH level of the working solution.

WHO classification, toxicity: hazard class IV.

Compatibility with other formulations: the formulation can be used together with fungicides, inoculants, pesticides, growth regulators, micronutrients and biological preparations.

Preparation and application of the formulation, working solution: the working solution is formed on the day of treatment according to the norms indicated on the label. The application rate of the formulation is 25-350 mL per 100 L of water, depending on the hardness of the water. To soften medium-hard water, 60 ml per 100 liters of water is sufficient.

Packaging unit: 5 liters.